Basic Properties
|
|
1)
|
Materials |
: |
Cross-linked, flexible, flame-retardant polyolefin resin
|
|
2)
|
Shrink temperature |
: |
90 min.
|
|
3)
|
Shrink ratio
(Radial change) |
: |
50% min.
|
| 4) |
Longitudinal change |
: |
-(5 5)%
|
|
5)
|
Continuous operating temperature |
: |
-55 to 125
|
|
|
Shrinkage-Temperature Curve |

The above curve chart shows the shrink ratio in each
direction. The shrink ratio in longitudinal direction should be indicated
with negative sign.
(ex. 15%
-15%) |
|
Top |
|
Features & Benefits
|
|
1)
|
UL224 and CSA recognition |
| 2) |
Flame-retardant |
| 3) |
Flexible |
| 4) |
Free of polybrominated biphenyl ethers(PBBEs),
polybrominated biphenyl oxides(PBBOs), polybrominated biphenyls(PBBs). |
| 5) |
Made in Sumi-Pac, Taiwan, only. |
|
|
Top |
|
Specifications / Approvals
|
|
|
UL224(5 Edition)
|
|
|
|
File No.: E48762
Catalogue No. : SUMITUBE F32
Operating temperature : 125
Voltage rating : 600V
Flammability rating : VW-1 |
|
|
|
|
|
|
|
|
|
|
|
|
CSA C22.2 No.198.1-99
|
|
|
|
Authorized file No. : LR84766
Operating temperature 125
Voltage rating : 600V
Flammability rating : VW-1 |
| |
|
| |
Electrical Appliance and Material Control Law
Optional Registration System of Compounds and Materials |
| |
|
Registration of flammability rating (-F-)
(Registration No. : F-SPE-001 to F-SPE-004) |
|
Top |
|
Top |
Applications |
|
1)
|
Insulation, protection and reinforcement of terminations
and joints of electric wires |
| 2) |
Color identification and bundling of electric wires
|
| 3) |
Insulation and protection of resistances and capacitors
|
|
Top |
Colors |
|
|
Standard colors |
: Black, brown, red, orange, yellow, green, blue, violet, gray
and white
|
|
Top |
Properties [UL224] |
|
Properties
|
Items
|
Requirements
|
Typical Values*
|
|
Mechanical
|
Tensile Strength
(before aging)
|
10.4MPa{1.06kg/mm2} min.
|
10.9MPa{1.11kgf/mm2}
|
|
Tensile Strength
(after aging)
|
158
7 days
Percent of original 70% min.
|
Percent of original 94%
|
|
Ultimate Elongation
(before aging)
|
200% min.
|
350%
|
|
Ultimate Elongation
(after aging)
|
158
7 days,
100% min.
|
320%
|
|
Flexibility
|
158
7 days,
No cracking
|
Pass
|
Heat Shock
|
250
4 hours,
No cracking
|
Pass
|
|
Cold Bend
|
-30
1 hour,
No cracking
|
Pass
|
|
Electrical
|
Dielectric Voltage Withstand
(before aging)
|
AC2.5kV
60sec.
No breakdown
|
Pass
|
|
Dielectric Voltage Withstand
(after aging)
|
158
7 days
AC2.5kV
60sec.
No breakdown
|
Pass
|
|
Dielectric Voltage Breakdown
(before aging)
|
AC2.5kV min.
|
24.8kV
|
|
Dielectric Voltage Breakdown
(after aging)
|
158
7 days
Percent of original 50%
AC2.5kV min.
|
Pass
|
|
Volume Resistivity
|
1014 cm
min.
|
4.4
1014 cm
|
|
Chemical
|
Copper Corrosion
|
After leaving for 24hours at humidity
95% and temperature 23
158
7 days, No corrosion
|
Pass
|
|
Copper Stability
|
After leaving for 24hours at humidity
95% and temperature 23
158
7 days
Ultimate Elongation 100% min.
|
338%
|
|
Flammability
|
Flame-retardant, Pass VW-1
|
Pass
|
|
*Not guaranteed values
|
|
Top |
Sizes |
|
Inch Sizes
|
|
Nominal Size (inch)
|
As Supplied (mm)
|
After Full Recovery (mm)
|
Unit Length (m)
|
|
Inside Diameter
|
Wall Thickness (nom.)
|
Inside Diameter (max.)
|
Wall Thickness (min.)
|
Cut
|
Spool
|
|
3/64
|
1.60 0.20
|
0.20
|
0.60
|
0.33
|
1.0
|
200
|
|
1/16
|
2.10 0.20
|
0.20
|
0.80
|
0.36
|
1.0
|
200
|
|
3/32
|
2.70 0.20
|
0.25
|
1.20
|
0.44
|
1.0
|
200
|
|
1/8
|
3.60 0.20
|
0.25
|
1.60
|
0.44
|
1.0
|
100
|
|
3/16
|
5.20 0.30
|
0.25
|
2.40
|
0.44
|
1.0
|
100
|
|
1/4
|
6.8 0.4
|
0.30
|
3.20
|
0.56
|
1.0
|
50
|
|
3/8
|
10.0 0.4
|
0.30
|
4.80
|
0.56
|
1.0
|
50
|
|
1/2
|
13.2 0.5
|
0.30
|
6.4
|
0.56
|
1.0
|
50
|
|
3/4
|
20.0 0.6
|
0.35
|
9.5
|
0.69
|
1.0
|
50
|
|
1
|
26.6 0.8
|
0.40
|
12.7
|
0.77
|
1.0
|
50
|
|
Top |
|
Metric Sizes
|
|
Nominal Size(mm)
|
As Supplied (mm)
|
After Full Recovery (mm)
|
Unit Length(min.)(m)
|
|
Inside Diameter
|
Wall Thickness
|
Inside Diameter (max.)
|
Wall Thickness (min.)
|
Cut
|
Spool
|
|
1
0.2
|
1.40 0.20
|
0.20
|
0.50
|
0.33
|
1
|
200
|
|
1.5
0.2
|
2.00 0.20
|
0.20
|
0.75
|
0.36
|
1
|
200
|
|
2
0.2
|
2.50 0.20
|
0.20
|
1.00
|
0.44
|
1
|
200
|
|
2.5
0.2
|
3.00 0.20
|
0.25
|
1.25
|
0.44
|
1
|
200
|
|
3
0.25
|
3.50 0.30
|
0.25
|
1.50
|
0.44
|
1
|
200
|
|
3.5
0.25
|
4.00 0.30
|
0.25
|
1.75
|
0.44
|
1
|
200
|
|
4
0.25
|
4.50 0.30
|
0.25
|
2.00
|
0.44
|
1
|
200
|
|
5
0.25
|
5.40 0.30
|
0.25
|
2.50
|
0.56
|
1
|
100
|
|
6
0.25
|
6.4 0.4
|
0.25
|
3.00
|
0.56
|
1
|
100
|
|
7
0.25
|
7.4 0.4
|
0.25
|
3.50
|
0.56
|
1
|
50
|
|
8
0.25
|
8.4 0.4
|
0.25
|
4.00
|
0.56
|
1
|
50
|
|
9
0.25
|
9.4 0.4
|
0.25
|
4.50
|
0.56
|
1
|
50
|
|
10
0.25
|
10.4 0.4
|
0.25
|
5.00
|
0.56
|
1
|
50
|
|
11
0.25
|
11.4 0.4
|
0.25
|
5.50
|
0.56
|
1
|
50
|
|
12
0.25
|
12.4 0.4
|
0.25
|
6.0
|
0.56
|
1
|
50
|
|
13
0.3
|
13.5 0.4
|
0.30
|
6.5
|
0.69
|
1
|
50
|
|
14
0.3
|
14.5 0.4
|
0.30
|
7.0
|
0.69
|
1
|
50
|
|
15
0.3
|
15.5 0.4
|
0.30
|
7.5
|
0.69
|
1
|
50
|
|
16
0.3
|
16.8 0.5
|
0.30
|
8.0
|
0.69
|
1
|
50
|
|
18
0.35
|
18.7 0.5
|
0.35
|
9.0
|
0.77
|
1
|
50
|
|
20
0.35
|
21.2 0.6
|
0.35
|
10.0
|
0.77
|
1
|
50
|
|
22
0.4
|
23.2 0.6
|
0.40
|
11.0
|
0.77
|
1
|
50
|
|
25
0.4
|
26.1 0.8
|
0.40
|
12.5
|
0.87
|
1
|
50
|
|
28
0.5
|
29.0 1.0
|
0.50
|
14.0
|
0.87
|
1
|
50
|
|
30
0.5
|
32.0 1.0
|
0.50
|
15.0
|
0.87
|
1
|
50
|
|
Top |
Caution! |
All statements and technical information contained herein are based on
tests we believe to be liable and only general properties are described.
Therefore, safety of each specific application by the users should not be
guaranteed. The users themselves should determine product conformance to
your specific applications and assume all responsibility for all damages
that may be caused directly or indirectly when using the products.
|
|